You are seeing this message because your Web browser does not support basic Web standards. Find out more about why this message is appearing and what you can do to make your experience on this site better.


ABOUT ARCHIVES
Advanced Search

Welcome   | My Account | E-mail Alerts | Access Rights | Sign In


  Vol. 121 No. 11, November 2003 TABLE OF CONTENTS
  Archives
  •  Online Features
  Laboratory Sciences
 This Article
 •Full text
 •PDF
 • Reply to article
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on ISI (1)
 •Contact me when this article is cited
 Related Content
 •Similar articles in this journal
 Topic Collections
 •Prostheses/ Implants
 •Facial Plastic Surgery
 •Biomaterials and Implants
 •Alert me on articles by topic

Magnetically Integrated Microporous Implant

Safety and Efficacy of Secondary Posting

Erika Escalona-Benz, MD; Matthew S. Benz, MD; Timothy G. Murray, MD; Brandy C. Hayden, BS; Eleut Hernandez; Scott N. Garonzik; Nicole L. Cicciarelli

Arch Ophthalmol. 2003;121:1596-1600.

Objective  To evaluate the surgical technique and morbidity related to secondary posting of a previously implanted 12-mm microporous high-density polyethylene implant (MEDPOR) and the enhanced motility associated with magnetic coupling of the prosthesis and the implant in a rabbit model.

Methods  Eight New Zealand rabbits underwent primary evisceration surgery with implantation of a 12-mm microporous high-density polyethylene implant. At 6 weeks, a 4 x 6-mm stainless steel, titanium-coated post was secondarily inserted in 6 rabbit eyes using a bilevel incision. Four weeks after the second surgery, 3 rabbits were fitted with a magnet-embedded prosthesis. Motility was measured by evaluating lateral prosthetic excursion during direct observation. At 3, 6, and 12 months the implants and surrounding tissues were harvested for histopathologic examination.

Results  Secondary placement of the post within the implant was accomplished without difficulty. No signs of erosion, dehiscence, or extrusion were found after a12-month follow-up in any of the study eyes. Clinical grading documented increased movement of the magnetically coupled prostheses compared with nonmagnetically integrated control eyes.

Conclusion  This study establishes the safety of secondary posting and the efficacy of magnetically integrated microporous high-density polyethylene implants in the rabbit model.

Clinical Relevance  This technique may offer an alternative to patients with previously implanted microporous high-density polyethylene implants seeking enhanced cosmesis and prosthetic motility.


From the Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami, Miami, Fla (Drs Escalona-Benz, Benz, and Murray and Mss Hayden and Cicciarelli, and Mr Hernandez); and the SNG Prosthetic Eye Institute, Boca Raton, Fla (Mr Garonzik). Mr Garonzik holds a patent on the integrated implant technology, licensed through Porex Corp, College Park, Ga.







HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | SUBMIT | SUBSCRIBE | HELP